| aluKOM-EX | ||||||||||||
![]() |
![]() |
![]() |
![]() |
|||||||||
Part No.
Ex e** |
Part No. Ex i** |
Part No. Ex leer (Empty)** |
Type
|
L |
W |
H |
D |
E |
Weight |
Drawings Download* |
||
PDF* |
DWG* |
|||||||||||
| AK 061 | 58 |
64 |
34 |
46 |
36 |
160g |
||||||
AK 062 |
98 |
64 |
34 |
86 |
36 |
220g |
||||||
AK 063 |
150 |
64 |
34 |
138 |
36 |
340g |
||||||
AK 081 |
75 |
80 |
57 |
63 |
52 |
290g |
||||||
AK 082 |
125 |
80 |
57 |
113 |
52 |
440g |
||||||
AK 083 |
175 |
80 |
57 |
163 |
52 |
530g |
||||||
AK 084 |
250 |
80 |
57 |
238 |
52 |
720g |
||||||
AK 120 |
122 |
120 |
81 |
106 |
82 |
950g |
||||||
AK 121 |
122 |
120 |
91 |
106 |
82 |
970g |
||||||
AK 122 |
220 |
120 |
81 |
204 |
82 |
1,420g |
||||||
AK 123 |
220 |
120 |
91 |
204 |
82 |
1,450g |
||||||
AK 124 |
360 |
122 |
81 |
344 |
82 |
1,860g |
||||||
AK 161 |
160 |
160 |
90 |
140 |
110 |
1,410g |
||||||
AK 162 |
260 |
160 |
90 |
240 |
110 |
1,950g |
||||||
AK 163 |
360 |
160 |
90 |
340 |
110 |
2,540g |
||||||
AK 164 |
560 |
160 |
90 |
540 |
110 |
4,310g |
||||||
AK 231 |
200 |
230 |
110 |
180 |
180 |
2,720g |
||||||
AK 232 |
280 |
230 |
110 |
260 |
180 |
3,850g |
||||||
AK 233 |
330 |
230 |
110 |
310 |
180 |
4,270g |
||||||
AK 234 |
400 |
230 |
110 |
380 |
180 |
4,880g |
||||||
AK 235 |
600 |
230 |
110 |
580 |
180 |
6,380g |
||||||
AK 311 |
402 |
310 |
110 |
382 |
261 |
6,300g |
||||||
AK 312 |
600 |
310 |
110 |
580 |
261 |
8,480g |
||||||
| Important Notes: ** Ex e & Ex i Models - Standard cases are supplied with a mounting rail and two terminals - please specify your requirements - Please download our Ex catalogue which gives full details of how many cable glands and terminals can be fitted under the certification - Please download and complete the Ex ordering check list to specify the number and type of cable glands and terminals you require (this must be within the maximum allowed by the certificate). ** Ex Leer - Empty enclosure with no cable glands, terminal rail or terminals. Your equipment must be retested once you have mounted your components. *PDF & DWG Drawings - These drawings are for standard non-Ex aluKOM enclosures, so are for dimensional reference only APPROVALS: II 2 GD Ex e |
||||||||||||
| OPTIONAL EXTRAS | ||||
![]() |
![]() |
![]() |
![]() |
![]() |
| For type.. | Part No. Internal Mounting Plate |
Part No. External Mounting Brackets |
Option Code External Hinges |
Option Code Internal Hinges |
| AK 061 | ||||
| AK 062 | ||||
| AK 063 | ||||
| AK 081 | ||||
| AK 082 | ||||
| AK 083 | ||||
| AK 084 | ||||
| AK 120 | ||||
| AK 121 | ||||
| AK 122 | ||||
| AK 123 | ||||
| AK 124 | ||||
| AK 161 | ||||
| AK 162 | ||||
| AK 163 | ||||
| AK 164 | ||||
| AK 231 | ||||
| AK 232 | ||||
| AK 233 | ||||
| AK 234 | ||||
| AK 235 | ||||
| AK 311 | ||||
| AK 312 | ||||
Order Example: |
||||
TECHNICAL DATA |
|
IP rating: |
IP66 / EN 60529 |
Material: |
Die-cast aluminium EN AC-44300 DIN EN 1706 (GD Al Si 12/DIN 1725) 1° mould slope for moulding ejection See material specifications for more information |
Finish/colour: |
Powder coat, silky grey, RAL 7032 Special finish & colours on request |
Surrounding temp: |
-20°C to +40°C |
Lid gasket: |
Oil & petrol resistant silicon gasket |
Lid screws: |
Captured stainless steel screws |
Internal mounting: |
Approved Ex e or Ex i terminals from several manufacturers |
Internal earth connection: |
Earth connection inside with earth-bar or PE-prints |
External earth connection: |
Outer earth connection in stainless steel |
Certification: |
GOST R (Russian Standards) |
Mounting: |
Separate screw ports outside of the enclosure interior |
|
|||||||||||||||||||||||||||||||||