polyTOP-Ex IP65 Polyester ATEX Hazardous Area Enclosures

polyTOP-Ex - IP65 Polyester ATEX Enclosures

Terminal housings for hazardous areas

 Home
 ..............................
 Contact Us
 ..............................
 Get a Catalogue
 ..............................
 Get a Quote
 ..............................
 Ordering Info
 ..............................

  FEATURES
  • ATEX terminal enclosures in glass-fibre
    re-inforced duro-plastic polyester

  • ATEX, EEx e, EEx i and EEx leer approvals
  • Corrosion proof stainless steel inserts
  • Large range of industry standard sizes
  • Supplied with pre-fitted DIN-Rails and terminals**
  • Optional allen head lid fixing screws
  • Internal screw bosses for mounting
    plates, PCB supports, Din-Rails etc.
  • Compatible ATEX cable glands
  EX APPROVALS
  • II 2 GD Ex e II T6 tD A21 T80°C IP65
  • II 2 GD Ex e ia IIC T6 tD A21 T80°C IP65
  • II 1 G Ex ia IIC T6 IP65
  • II 2 GD Ex e II tD A21 IP66
  • KEMA 02ATEX2053
  • KEMA 02ATEX2053 U
  • 2ExellT6 DIP A21 TA 80°C
  • 0ExiallCT6 DIP A21 TA 80°C
  • ExellU DIP A21 TA 80°C
  ACCESSORIES
  • Internal mounting plate
  • External mounting brackets
  • External hinges
  • Terminal mounting rail
DATASHEETS
Download PDF file Ex catalogue
Download PDF file Ex ordering check list
Download PDF file IP rating certificate
Download PDF file ATEX certificate (Terminal Case)
Download PDF file ATEX certificate (Empty Case)
Download PDF file Lid screws max. torque
Download PDF file DIN 40050 - IP ratings
Download CAD Drawing 3D-Drawings download

polyTOP-Ex IP65 Polyester Electrical Enclosures for hazardous areas
Ex e and Ex i  approved cable glands Earth bar Terminal and terminal rails






 polyTOP-EX
polyTOP-Ex e Enclosures
polyTOP-Ex i Enclosures polyTOP-Ex leer Enclosures polyTOP-Ex External Dimensions
Part No.
Ex e**
Part No.
Ex i**
Part No.
Ex leer
(Empty)
 Type
L
W
H
D
E
Weight
Drawings
Download*
PDF*
DWG*
137.080.000
139.080.000
138.080.000
 PT 080
82
82
60
67
67
240g
Download PDF Drawing
Download DWG Drawing
137.082.000
139.082.000
138.082.000
 PT 082
122
82
60
107
67
340g
Download PDF Drawing
Download DWG Drawing
137.084.000
139.084.000
138.084.000
 PT 084
162
82
60
147
67
420g
Download PDF Drawing
Download DWG Drawing
137.100.000
139.100.000
138.100.000
 PT 100
102
102
81
87
78
520g
Download PDF Drawing
Download DWG Drawing
137.102.000
139.102.000
138.102.000
 PT 102
152
102
81
137
87
650g
Download PDF Drawing
Download DWG Drawing
137.104.000
139.104.000
138.104.000
 PT 104
202
102
81
187
87
770g
Download PDF Drawing
Download DWG Drawing
137.120.000
139.120.000
138.120.000
 PT 120
124
124
100
102
102
800g
Download PDF Drawing
Download DWG Drawing
137.122.000
139.122.000
138.122.000
 PT 122
184
124
100
162
102
860g
Download PDF Drawing
Download DWG Drawing
137.124.000
139.124.000
138.124.000
 PT 124
244
124
100
222
102
920g
Download PDF Drawing
Download DWG Drawing
137.160.000
139.160.000
138.160.000
 PT 160
164
164
100
142
142
820g
Download PDF Drawing
Download DWG Drawing
137.162.000
139.162.000
138.162.000
 PT 162
244
164
100
222
142
1,100g
Download PDF Drawing
Download DWG Drawing
137.164.000
139.164.000
138.164.000
 PT 164
324
164
100
302
142
1,340g
Download PDF Drawing
Download DWG Drawing
137.400.000
139.400.000
138.400.000
 PT 400
404
404
160
382
382
6,500g
Download PDF Drawing
Download DWG Drawing
 Important Notes:
 ** Ex e & Ex i Models - Standard cases are supplied with a mounting rail and two terminals - please specify your requirements
 - Please download our Ex catalogue which gives full details of how many cable glands and terminals can be fitted under the certification
 -
Please download and complete the Ex ordering check list to specify the number and type of cable glands and terminals you
   require (this must be within the maximum allowed by the certificate).
 ** Ex Leer - Empty enclosure with no cable glands, terminal rail or terminals. Your equipment must be retested
   once you have mounted your components.
 *
PDF & DWG Drawings - These drawings are for standard non-Ex aluKOM enclosures, so are for dimensional reference only





 ACCESSORIES
blank insert Internal mounting plate
External mounting brackets
External hinges
Terminal mounting rails
 For type..
Part No.
Internal
Mounting
Plate
Part No.
External
Mounting
Brackets

Option Code
External
Hinges
Option Code
Terminal
Mounting
Rail
 PT 080
507.080.000
501.000.005
 
T
 PT 082
507.082.000
501.000.005
 
T
 PT 084
507.084.000
501.000.005
 
T
 PT 100
507.100.000
501.000.005
 
T
 PT 102
507.102.000
501.000.005
S
T
 PT 104
507.104.000
501.000.005
S
T
 PT 120
507.120.000
501.000.001
S
T
 PT 122
507.122.000
501.000.001
S
T
 PT 124
507.124.000
501.000.001
S
T
 PT 160
507.160.010
501.000.001
S
T
 PT 162
507.162.010
501.000.001
S
T
 PT 164
507.164.000
501.000.001
S
T
 PT 400
507.400.000
501.000.001
S
T

 Order Example:
 Case PT 124 with internal mounting plate and external hinges
 Order case Part No. 132.124.000 + 507.124.000 + S
 We will supply the case pre-fitted with the mounting plate and hinges




TECHNICAL DATA
IP rating:
IP65 / EN 60529
Material:
Polyester, glass-fibre reinforced halogen-free
1° mould slope for moulding ejection
See material specifications for more information
Combustion behaviour:
UL 94 V-0
Surface resistance:
> 109 Ω
Colour:
Black, similar to RAL 9011
Surrounding temp:
-40°C to +40°C
Lid gasket:
Oil & petrol resistant silicon gasket
Lid screws:
Captured slot head polyamide screws (optional allen head type)
Internal mounting:
Approved Ex e or Ex i terminals from several manufacturers
Internal earth connection:
Earth point (models PT 080 to PT 104), or earth-bar (models PT 120 to PT 400)
Mounting:
Common screw ports for external mounting and lid fixing screw, outside the sealed area
Certification:
CSA (UL 508 industrial control equipment)
GOST R
(Russian Standards)


 
Get a Catalogue
Customising Services
 
 Get a Catalogue
Customising
       
       
           
ROLEC SITE LINKS
 
Rolec Enclosures
 
           
Tel: (01489) 583858  Last Updated: 03-Feb-2010 ©OKW Enclosures Ltd. UK. All rights reserved.